Thermal Shorts Prevention Brooklyn NY

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? Read on to find the answer or turn to building construction consultants in Brooklyn for help.

E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Services
Landscape Designers & Consultants, Patio Porch Deck & Gazebo Builders, Masonry Contractors, Deck Designers & Builders, Brick Walkways & Patios
Hours
Mon 08: 00 AM-06: 00 PM
Tue 08: 00 AM-06: 00 PM
Wed 08: 00 AM-06: 00 PM


Jameson Mark
(201) 386-1500
Hoboken Area
Jersey City, NJ
 
Ugolini Elio Mason Contractor
(201) 433-4304
213 Harrison Ave
Jersey City, NJ
 
Willow Snow Removal
(201) 659-7266
67 Pollock Ave
Jersey City, NJ
 
Villa Stucco
(201) 653-9447
54 Jefferson Ave
Jersey City, NJ
 
Anton Haddad Plumbing & Heating
(201) 792-1587
15 Saddlewood Ct
Jersey City, NJ
 
Clean Flow
(732) 985-1934
53 Bartha Ave
Jersey City, NJ
 
Willow Run Construction
(201) 659-7266
67 Pollock Ave
Jersey City, NJ
 
Hatiya Contracting Inc
(718) 395-7744
9322 74th Place
Woodhaven, NY
 
Jetco Unlimited Exterior Building Restoration & Maintenance
(201) 798-3178
268 New York Ave
Jersey City, NJ
 

Thermal Shorts Prevention

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: February 1, 2005

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? These brackets typically disrupt the batt insulation within the wall cavity above the windows, which creates cold spots where condensation can form.

Angle brackets such as these can form a significant thermal bridge from the exterior to the interior. Depending on the interior climate conditions, these thermal bridges can create condensation problems in many areas, especially in the northern portions of the United States.

One way to reduce this thermal bridge is to insulate the cavity space instead of the stud space. In this design, all the insulation is placed in the cavity and no insulation is put within the stud space. Although this approach does not completely eliminate the thermal transfer of the shelf angle, it greatly reduces the problem.

Thermal transfer is further reduced by using plastic shims between the angle and the bracket in a bolted assembly. The heads of the windows below these angles also should be insulated to isolate them from the cold angle.