Thermal Shorts Prevention Buffalo NY

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? Read on to find the answer or turn to building construction consultants in Buffalo for help.

Ajax Smith, Inc.
(716) 877-1126
4000 River Rd.
Tonawanda, NY
 
E J Militello Concrete Inc
(716) 636-2288
6465 Transit Rd
East Amherst, NY
 
Summit Paving and Masonry
(631) 464-7054
30 Kelsey Ave
Huntington Station, NY
Services
Stone Masonry Construction, Masonry Construction, Masonry Services, Walkways, Drains, Hardscapes, Stone Steps, Masonry Company, Asphalt, Paving, Patios, Pools, Stamped Concrete, Pavers, Driveways, Masonry Work, Retaining Walls, Concrete Repair, Asphalt Repair, Paving Service, Masonry Service, Parking Lots, Overlays, Drainage Systems, Stoops, Waterfalls, Steps, Private Roads, Garage Slabs, Foundations, Excavation, Curbs, Stucco Work, Power Washing, Seal Coating
Hours
Open 7 days a week from 7:00am-7:30pm
Membership Organizations
Licensed, Insured, and Bonded.

Capstone Construction
(631) 784-7701
775 Park Ave
Huntington, NY
 
ADS Masonry
(585) 698-0756
1900 university ave
rochester , NY
Services
Stone & Decorative concrete
Hours
8-5

DM Padovano Construction
(716) 553-7447
320 Irvington Dr
Tonawanda, NY
 
Peter Home Improvements Corp
(718) 699-8441
5841 Waldron St
Flushing, NY
 
Kneeland Constr Co
(518) 452-7320
25 Corporate Cir Ste 3
Albany, NY
 
Di Pace Masonry Inc
(518) 459-1834
1 Kneeland St
Albany, NY
 
Colonie Masonry Corp Of Albany Inc
(518) 370-2471
1971 Western Ave # 231
Albany, NY
 

Thermal Shorts Prevention

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: February 1, 2005

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? These brackets typically disrupt the batt insulation within the wall cavity above the windows, which creates cold spots where condensation can form.

Angle brackets such as these can form a significant thermal bridge from the exterior to the interior. Depending on the interior climate conditions, these thermal bridges can create condensation problems in many areas, especially in the northern portions of the United States.

One way to reduce this thermal bridge is to insulate the cavity space instead of the stud space. In this design, all the insulation is placed in the cavity and no insulation is put within the stud space. Although this approach does not completely eliminate the thermal transfer of the shelf angle, it greatly reduces the problem.

Thermal transfer is further reduced by using plastic shims between the angle and the bracket in a bolted assembly. The heads of the windows below these angles also should be insulated to isolate them from the cold angle.

Click here to read full article from Masonry Construction