Thermal Shorts Prevention Ithaca NY

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? Read on to find the answer or turn to building construction consultants in Ithaca for help.

D P Building Co
(315) 395-8608
3650 James St Ste 211
Syracuse, NY
 
SLR Industries Inc.
(631) 893-3934
411 Broadway
West Babylon, NY
Services
Patios, Driveways, Walks, Pools
Hours
7am to 530pm

Viau Constr Corp
(315) 472-0171
785 Erie Blvd W
Syracuse, NY
 
Lari Construction Limited
(315) 701-0444
2572 Erie Blvd E Ste 2
Syracuse, NY
 
Kneeland Constr Co
(518) 452-7320
25 Corporate Cir Ste 3
Albany, NY
 
Cotumaccio Luigi Masonry Contrctng Co
(718) 776-2661
9071 198th St
Jamaica, NY
 
Seven Stars Construction Inc
(631) 451-1787
911 Old Medford Ave
Medford, NY
Services
Masonry contractor, Masonry, Brick Driveways, Retaining walls, Stone Walkways, Stone walls, Stone Steps, Stone Patios, Brick Patios, Brick Wood fire ovens, Chimney's, Stucco, Stone face, Pools, Columns, Brick face, Bluestone veneer, Stamp concrete
Hours
Open Daily 9am - 5pm
Membership Organizations
BBB

Pezzino Nely
(718) 358-1481
2221 Parsons Blvd
Flushing, NY
 
A La Marca Construction
(718) 526-7795
14402 91st Ave
Jamaica, NY
 
Hopkins & Reilly Mason Contractors Inc
(315) 474-0161
419 Hiawatha Blvd E
Syracuse, NY
 

Thermal Shorts Prevention

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: February 1, 2005

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? These brackets typically disrupt the batt insulation within the wall cavity above the windows, which creates cold spots where condensation can form.

Angle brackets such as these can form a significant thermal bridge from the exterior to the interior. Depending on the interior climate conditions, these thermal bridges can create condensation problems in many areas, especially in the northern portions of the United States.

One way to reduce this thermal bridge is to insulate the cavity space instead of the stud space. In this design, all the insulation is placed in the cavity and no insulation is put within the stud space. Although this approach does not completely eliminate the thermal transfer of the shelf angle, it greatly reduces the problem.

Thermal transfer is further reduced by using plastic shims between the angle and the bracket in a bolted assembly. The heads of the windows below these angles also should be insulated to isolate them from the cold angle.

Click here to read full article from Masonry Construction