Thermal Shorts Prevention Utica NY

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? Read on to find the answer or turn to building construction consultants in Utica for help.

Kabinet King
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
 
Agl Land Design Inc
(631) 673-2854
19 Duncan Ln
Huntington, NY
 
Alpha Design Corp
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
 
Heritage Masonry Restoration
(315) 423-9889
421 Burnet Ave
Syracuse, NY
 
Malatesta Paladino Inc
(718) 523-5656
13919 109th Ave
Jamaica, NY
 
Patriot Masonry & Construction,Inc.
(607) 988-6561
81 Willow St
Otego, NY
Services
Full Masonry & Construction services
Hours
M-F 8am-5pm

Anastasio Inc
(631) 499-1777
1633 E Jericho Tpke
Huntington, NY
 
Summit Paving and Masonry
(631) 464-7054
30 Kelsey Ave
Huntington Station, NY
Services
Stone Masonry Construction, Masonry Construction, Masonry Services, Walkways, Drains, Hardscapes, Stone Steps, Masonry Company, Asphalt, Paving, Patios, Pools, Stamped Concrete, Pavers, Driveways, Masonry Work, Retaining Walls, Concrete Repair, Asphalt Repair, Paving Service, Masonry Service, Parking Lots, Overlays, Drainage Systems, Stoops, Waterfalls, Steps, Private Roads, Garage Slabs, Foundations, Excavation, Curbs, Stucco Work, Power Washing, Seal Coating
Hours
Open 7 days a week from 7:00am-7:30pm
Membership Organizations
Licensed, Insured, and Bonded.

SLR Industries Inc.
(631) 893-3934
411 Broadway
West Babylon, NY
Services
Paving Masonry
Hours
7am to 5pm, Mon thru Fri
Awards
Best on Long Island
Membership Organizations
ICPI, LIAPMA

Prima Plastering Inc
(631) 427-8699
77 Soundview Rd
Huntington, NY
 

Thermal Shorts Prevention

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: February 1, 2005

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? These brackets typically disrupt the batt insulation within the wall cavity above the windows, which creates cold spots where condensation can form.

Angle brackets such as these can form a significant thermal bridge from the exterior to the interior. Depending on the interior climate conditions, these thermal bridges can create condensation problems in many areas, especially in the northern portions of the United States.

One way to reduce this thermal bridge is to insulate the cavity space instead of the stud space. In this design, all the insulation is placed in the cavity and no insulation is put within the stud space. Although this approach does not completely eliminate the thermal transfer of the shelf angle, it greatly reduces the problem.

Thermal transfer is further reduced by using plastic shims between the angle and the bracket in a bolted assembly. The heads of the windows below these angles also should be insulated to isolate them from the cold angle.