Thermal Shorts Prevention Utica NY

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? Read on to find the answer or turn to building construction consultants in Utica for help.

Rapid Masonry Restoration
(718) 424-8304
7906 37th Ave
Jackson Heights, NY
 
A La Marca Construction
(718) 526-7795
14402 91st Ave
Jamaica, NY
 
Colonie Masonry Corp Of Albany Inc
(518) 370-2471
1971 Western Ave # 231
Albany, NY
 
Empire Paving & Masonry
(631) 482-2478
56 Amityville Rd
Melville, NY
Services
construction company, asphalt, paving, patios, pools, stamped concrete, paving, driveways, masonry work, retaining wall
Hours
Open 7 days a week from 7:00am-7:30pm
Membership Organizations
Licensed, Insured, Bonded, Member of BBB, and Chamber of Commerce.

Hatiya Contracting Inc
(718) 395-7744
9322 74th Place
Woodhaven, NY
 
Anastasio Inc
(631) 499-1777
1633 E Jericho Tpke
Huntington, NY
 
Chimney Wizards
(518) 427-7603
100 Lark St
Albany, NY
 
Academic Stone Setters Inc
(718) 463-7395
2907 119th St
Flushing, NY
 
E J Militello Concrete Inc
(716) 636-2288
6465 Transit Rd
East Amherst, NY
 
J & C Masonry and Landscaping Inc.
(914) 941-8146
198 Spring Street
Ossining, NY
 

Thermal Shorts Prevention

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: February 1, 2005

When angles are suspended from the structure above with triangular brackets in brick veneer over steel stud backup walls, is there any efficient way to prevent the thermal short that typically occurs where the steel angle attaches to the bracket? These brackets typically disrupt the batt insulation within the wall cavity above the windows, which creates cold spots where condensation can form.

Angle brackets such as these can form a significant thermal bridge from the exterior to the interior. Depending on the interior climate conditions, these thermal bridges can create condensation problems in many areas, especially in the northern portions of the United States.

One way to reduce this thermal bridge is to insulate the cavity space instead of the stud space. In this design, all the insulation is placed in the cavity and no insulation is put within the stud space. Although this approach does not completely eliminate the thermal transfer of the shelf angle, it greatly reduces the problem.

Thermal transfer is further reduced by using plastic shims between the angle and the bracket in a bolted assembly. The heads of the windows below these angles also should be insulated to isolate them from the cold angle.